Add Makefile, rename files and add troubleshooting in documentation
This commit is contained in:
parent
fa1a05d88c
commit
7b21d0753e
4
Makefile
Normal file
4
Makefile
Normal file
@ -0,0 +1,4 @@
|
||||
# Makefile
|
||||
|
||||
main:
|
||||
gcc everblu_meters.c -o everblu_meters -lwiringPi -lpthread -Wall
|
33
README.md
33
README.md
@ -1,10 +1,14 @@
|
||||
# everblu-meters
|
||||
Fetch water usage data from Cyble EverBlu meters using RADIAN protocol.
|
||||
Fetch water/gas usage data from Cyble EverBlu meters using RADIAN protocol on 433Mhz.
|
||||
|
||||
Meters supported:
|
||||
- Itron EverBlu Cyble Enhanced
|
||||
|
||||
|
||||
|
||||
## Hardware
|
||||

|
||||
Currently the project runs on Raspberry Pi with an RF transreciver (CC1101).
|
||||
The project runs on Raspberry Pi with an RF transreciver (CC1101).
|
||||
|
||||
### Connections (rpi to CC1101):
|
||||
- pin 1 (3V3) to pin 2 (VCC)
|
||||
@ -20,28 +24,29 @@ Currently the project runs on Raspberry Pi with an RF transreciver (CC1101).
|
||||
## Configuration
|
||||
1. Enable SPI in raspi-config.
|
||||
2. Install WiringPi from https://github.com/WiringPi/WiringPi/
|
||||
3. Set meter serial number and production date in `cc1101.c`, it can be found on the meter label itself:
|
||||
3. Install mosquitto-dev: `apt install mosquitto-dev`
|
||||
4. Set meter serial number and production date in `cc1101.c`, it can be found on the meter label itself:
|
||||

|
||||
5. Compile the code with `make`
|
||||
6. Run `everblu_meters`, after ~2s your meter data should be on the screen.
|
||||
|
||||
|
||||
|
||||
|
||||
## Compiling
|
||||
|
||||
```
|
||||
gcc radian_trx.c -o radian_trx -lwiringPi -lpthread -Wall
|
||||
```
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
### Frequency adjustment
|
||||
Your transreciver module may be not calibrated correctly, please modify frequency a bit lower or higher and try again
|
||||
|
||||
|
||||
### Business hours
|
||||
Your meter may be configured in such a way that is listens for request only during hours when data collectors work - to conserve energy. If you are unable to communicate with the meter, please try again during business hours (8-16).
|
||||
|
||||
### Serial number starting with 0
|
||||
Please ignore the trailing 0, provide serial in configuration whthout it.
|
||||
|
||||
|
||||
## Origin and license
|
||||
|
||||
This code is fetched from http://www.lamaisonsimon.fr/wiki/doku.php?id=maison2:compteur_d_eau:compteur_d_eau
|
||||
|
||||
This code is based on code from http://www.lamaisonsimon.fr/wiki/doku.php?id=maison2:compteur_d_eau:compteur_d_eau
|
||||
|
||||
|
||||
The license is unknown, citing one of the authors (fred):
|
||||
@ -50,5 +55,3 @@ The license is unknown, citing one of the authors (fred):
|
||||
> this code was made by "looking" at the radian protocol which is said to be open source earlier in the page, I don't know if that helps?
|
||||
|
||||
|
||||
|
||||
|
||||
|
@ -2,7 +2,7 @@
|
||||
/* it is exposed just to demonstrate CC1101 capability to reader water meter indexes */
|
||||
/* there is no Warranty on radian_trx SW */
|
||||
|
||||
#include "radian_trx.h"
|
||||
#include "everblu_meters.h"
|
||||
|
||||
void IO_init(void)
|
||||
{
|
Loading…