everblu-meters

Fetch water usage data from Cyble EverBlu meters using RADIAN protocol.

Hardware

Currently the project runs on Raspberry Pi with an RF transreciver (CC1101).

Configuration

You will need serial number of the meter, it can be found on the meter label itself Cyble Meter Label

CC1101.c : line 664 : TS_len_u8=Make_Radian_Master_req(txbuffer, 16 , 123456 );

Compiling

gcc radian_trx.c -o radian_trx -lwiringPi -lpthread -Wall

Troubleshooting

Origin and license

This code is fetched from http://www.lamaisonsimon.fr/wiki/doku.php?id=maison2:compteur_d_eau:compteur_d_eau

The license is unknown, citing author (fred):